Eight settings are available for the tone of the beeper normal, 6 alternate tones and no tone. One Beep The scanner will beep once after communication has been established and the unit is properly placed into the cradle. When the scanner successfully reads a bar code, the scanners white LED will flash and the unit will beep once.

When the CodeGate button is pressed for 3 seconds, the scanner will indicate it has entered full sleep mode with a extended beep. Two Beeps When the scanner has a low battery voltage, it will emit two beeps after a successful scan and flash the amber LED every 5 seconds.

When communication has been broken between the scanner and cradle, the scanner will emit two combined high and low tones while the blue LED flashes. Three Beeps When entering configuration mode, the white LED will flash while the scanner simultaneously beeps three times. When exiting configuration mode, the scanner will beep three times and the white LED will stop flashing.

When using single-code-Configuration, the scanner will sound a 3-combination tone a short pause followed by a high tone and a low tone. This indicates a single configuration bar code has successfully configured the scanner. When scanning a Bluetooth address bar code, the scanner will beep three times. The scanners blue LED will start to flash as it attempts to establish a communication link.

The scanner will emit a 3-combination tone and the blue LED will stop flashing, staying steadily illuminated to indicate communication between the scanner and the cradle has been successfully established. Razzberry Tones This tone indicates a type of failure. Refer to Failure Modes" on page When the scanner is in operation, the flashing or stationary activity of the LEDs indicates the status of the scanner and the current scan. The scanner is in full sleep mode. Press the CodeGate button to wake the scanner from full sleep mode.

The blue LED will start to flash as the unit exits full sleep mode. Steady Amber After establishing communication, when the scanner is put into the cradle and the battery has been fully charged, the amber LED will remain steady. If the communication is not established, when the scanner is put into the cradle, the amber LED will stay on after a short delay. The blue LED will remain illuminated until the laser is deactivated. If the scanner reads the bar code successfully at a relatively long distance but still within the meter operation range, the white LED may flash after a short delay.

Steady Blue and Steady White After a successful scan, the scanner transmits the data to the cradle. If the cradle is not ready to accept the information, the scanners white LED will remain on until the data can be transmitted or until a communication time-out occurs. Two razzberry tones indicate that an invalid bar code has been scanned while in this mode.

If the scanner needs to have a Flash ROM upgrade, the alternating flashing of the blue and white LEDs will occur during startup and is accompanied by three beeps. Steady White, Blue off This indicates the laser is off and the scanner is still waiting for communication from the cradle. Flashing Blue The blue LED on the scanner and the cradle indicates the connecting status of the cradle with the scanner.

When the Bluetooth connection breaks, the blue LED will flash. This indicates the scanner is trying to establish communication with the cradle. A single blue flash on the cradle indicates data has been received from the scanner. Flashing Amber When scanner is in the cradle, a flashing amber LED indicates the scanner is being charged. When the scanner is out of cradle, a flashing amber LED indicates the scanner has low battery power and needs recharging.

Return the unit for repair to an authorized service center. Flashing Blue and White with Two Razzberry Tones This indicates the scanner has experienced a scanning mechanism failure. Continuous Razzberry Tone with all LEDs off If the scanner emits a continuous razzberry tone upon power-up, the scanner has experienced an electronic failure. Three Beeps on power up If the scanner beeps 3 times on power-up then the non-volatile memory NovRAM that holds the scanner configuration has failed.

If the scanner does not respond after reconfiguring, return the scanner for repair to an authorized service center. Two Razzberry Tones with Steady White When the scanner scans a bar code without establishing Bluetooth communication first, the scanner will emit two razzberry tones and the white LED will stay steadily lit. The scanner reads a bar code but the cradle fails to transmit the data. Long Beeps with Steady Amber LED The scanner will emit a long beep every 5 second indicating the scanner's contacts are not making a physical connection with the charging contacts on the cradle.

Proper placement of the scanner in the cradle is essential for the charging process. Locate the small pinhole on the bottom of the cradle near the cable. Bend an ordinary paperclip into the shape shown above. Insert the paperclip or the small metallic pin into the small pin-hole. Cable Release. You will hear a faint click. Pull gently on the strain-relief of the pin, RJ45 cable to remove the cable from the cradle.

Cradle Wall Mount Metrologic provides two 7 wood screws for securing the cradle to the wall. Figure 15 provides the pilot hole dimensions for securing the cradle base. Contact a Metrologic representative at ID-Metro or to preserve the limited warranty terms. Symptoms The scanner has no LEDs, beeper or laser while seated in cradle.

The scanner has no LEDs, beeper or laser when out of the cradle. The scanner locks up after the first scan. The white LED stays on and the unit razzes twice. The scanner locks up after scanning a bar code. The scanner emits 2 beeps with alternately flashing LEDs on power-up. Possible Causes Solution Check the transformer, outlet and power strip.

Verify the power cable is plugged into the cradle properly. The distance between scanner and cradle is beyond the meter operation range and RangeGate is not activated. The scanner emits a continuous razz tone on power up.

Solution Contact a Metrologic customer service representative, if the unit will not hold the configuration. The scanner emits a razz tone A scanning and both the blue mechanism failure and white LEDs may have occurred. The scanner The same symbol scans, timeout is set too communicates short. The bar code being scanned does not satisfy the scanners configured criteria i.

Adjust the same symbol timeout for a longer time. Verify that the type of bar code being read has been selected. Verify that the bar code that is being scanned falls into the criteria. The white LED stays on. The scanner scans, but the data transmitted to the host is incorrect. Possible Causes The scanner is configured to support some form of host handshaking but is not receiving the signal. Verify that the scanners data format matches that required by the host.

Most sure that the scanner is connected to the proper host port. The scanner beeps at some The print quality of bar codes and the bar code is NOT for others suspect.

The aspect ratio of the bar code is out of tolerance. The bar code may have been printed incorrectly. The scanner is not configured correctly for this type of bar code. The minimum symbol length setting does not work with the bar code. Characters are being dropped. Inter-character delay needs to be added to the transmitted output. Check the print mode. The type of printer could be the problem. Change the print settings i.

Check print mode. Change print settings. Check if the correct minimum symbol length is set. The scanner scans but the data is not correct. The scanner is transmitting each character twice. Alpha characters show as lower case characters. Everything works except for a couple of characters. Solution Make sure the scanner is configured for the appropriate mode.

Verify correct country code and data formatting are selected. Adjust inter-character delay symptom. Increase the interscan code delay setting.

Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings. Try operating the scanner in Alt mode. Check to make sure that the baud rate, parity of the scanner, and the communication port match. Check to make sure the configuration is looking for RS data. Check to make sure the communication cable is securely connected to the host and cradle and that the cable is connected to the correct com port on the host. Check that the cradle and the host are configured for the same interface parameters.

The computer is in Caps Lock mode. These characters may not be supported by that countrys key look up table. Com port at the host is not working or configured properly. The cable is not connected to the proper com port. The cradle and host may not be configured for the same interface parameters. Mechanical Length: Width: Depth: Weight: mm 7.

The scanner and cradle are shipped from the factory configured to a set of default conditions. Every communication does not support every parameter. If the communication supports a parameter listed in the charts on the following pages, a check mark will appear.

It requires the use of a personal computer running under Windows 95 or greater and the use of a communication port. The user merely connects the scanners cradle to a communication port on the PC, launches the MetroSet 2 program, and blasts off to new software upgrades. Each MS and its cradle, regardless of the version number or communication protocol, can be upgraded.

Communication between the scanner and the cradle must be established before upgrading the flash ROM within the scanner. The upgrades and custom software versions will be supplied by Metrologic in files called Motorola S-record files. These files contain all the information needed to upgrade the scanner. Simply add this file to the working directory or retrieve the file from its current location. The program guides the user with a simplistic one click approach. The user must first select the file.

Once selected and verified, the file is ready to be used in the upgrade. Press the button to start the upgrading. Contact a Metrologic customer service representative for additional details on upgrading flash ROM firmware. Please refer to this guide for instructions. MetroSet2 This user-friendly Windows-based configuration program allows you to simply point-and-click at the desired scanner options. It basically simulates the scanning of the configuration bar codes, but through the serial port.

The number of ports and type of connection varies by cradle model and the interface required. The following charts provide the pinout information for the different cradle models and interfaces available.

Cradle MI Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. According to the termination required, connect the appropriate end of the adapter cable to the PowerLink cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC. Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.

Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure.

The use of optical instruments with the laser equipment will increase eye hazard. Atencin La modificacin de los procedimientos, o la utilizacin de controles o ajustes distintos de los especificados aqu, pueden provocar una luz de lser peligrosa. Bajo ninguna circunstancia el usuario deber realizar el mantenimiento del lser del escner.

Ni intentar mirar al haz del lser incluso cuando este no est operativo. Tampoco deber abrir el escner para examinar el aparato. El hacerlo puede conllevar una exposicin peligrosa a la luz de lser. El uso de instrumentos pticos con el equipo lser puede incrementar el riesgo para la vista.

Attention L'emploi de commandes, rglages ou procds autres que ceux dcrits ici peut entraner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir luimme le scanner ou le laser. Ne regardez jamais directement le rayon laser, mme si vous croyez que le scanner est inactif.

N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez une rayonnement laser q st hazardous. L'emploi d'appareils optiques avec cet quipement laser augmente le risque d'endommagement de la vision. Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefhrliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umstnden versuchen, den Laser-Scanner selbst zu warten.

Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, da der Scanner nicht aktiv ist. Wenn Sie dies tun, knnen Sie sich einer gefhrlichen Laserstrahlung aussetzen. Attenzione Lutilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale pu provocare delle esposizioni a raggi laser rischiose.

Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai il raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro lapparecchio. Facendolo potete esporVi ad una esposizione laser rischiosa. Luso di apparecchi ottici, equipaggiati con raggi laser, aumenta il rischio di danni alla vista..

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense.

Any unauthorized changes or modifications to this equipment could void the users authority to operate this device. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1 This device may not cause harmful interference, and 2 this device must accept any interference received, including interference that may cause undesired operation.

The radiated output power of this intentional wireless radio is far below the FCC radio frequency exposure limits.

The internal wireless radio operates within guidelines found in radio frequency safety standards and recommendations, which reflect the consensus of the scientific community. The level of energy omitted is far less than the electromagnetic energy emitted by wireless devices such as mobile phones.

However, the use of wireless radios may be restricted in some situations or environments, such as aboard airplanes. If you are unsure of restrictions, you are encouraged to ask for authorization before turning on the wireless radio.

European Standard Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Funkstreigenschaften nach EN Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstrungen verursachen. In diesem Fall kann vom Betreiber verlangt werden, angemessene Massnahmen durchzufhren. Standard Europeo Attenzione Questo e un prodotto di classe A.

Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere allutilizzatore opportune misure. Attention Ce produit est de classe A. Dans un environnement domestique, ce produit peut tre la cause dinterfrences radio. Dans ce cas lutiliseteur peut tre amen predre les measures adquates. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. A facility and its Suzhou, China facility. Metrologic warrants and represents that all MS VoyagerBT scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.

Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of product or refund of product price at the sole discretion of Metrologic.

This limited warranty does not extend to any Product which, in the sole judgment of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if the case of Product is opened by anyone other than Metrologics repair department or authorized repair centers. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of Page 5: Introduction The cradle of the Voyager When resting in the cradle, the scanner can reach a fully charged state in 2.

When fully charged, the scanner can provide up to 12, scans. For power saving, the scanner can be put into a full sleep mode by depressing the CodeGate button for 5 seconds after the laser has shut down.

The blue LED on the rear of the cradle will stay on. Pick up the scanner and scan the Bluetooth address code on the cradle; you will hear 3 continuous beeps. After 4 seconds, both the blue LEDs of the charger cradle and the scanner flashes, followed by 2 combination beeps.

Page 8 Auto-trigger mode When the scanner is at rest in the cradle, it is in auto-trigger mode. While in this mode, present a bar code in the scanning field and the data is automatically decoded and transmitted.

To maintain compliance with standard CSA C Page Ibm Scanner Installation Turn on the host system. Once a cradle is paired with a scanner, another scanner can not be paired with that cradle until the connection is broken.

The connection can be easily broken by placing the unit into sleep mode by holding down the CodeGate button for three 3 seconds. For normal sleep mode, scan the configuration bar codes in the Bluetooth Programming Addendum A. As a receiver, after establishing Bluetooth communication with the scanner, the cradle receives date being scanned by the scanner and transmits it to the host.

To communicate with different host interfaces, the cradle is offered in various configurations. When the scanner associated with the cradle can not be found, press the page button; the scanner will begin beeping and the blue and amber LEDs will flash alternatively. Page Audible Indicators When the scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beeper normal, 6 alternate tones and no tone.

When the scanner is in operation, the flashing or stationary activity of the LEDs indicates the status of the current scan and the scanner. Page 23 LEDs will occur during startup and is accompanied by three beeps. Steady White, Blue off This indicates the laser is off and the scanner is still waiting for communication from the cradle. Flashing Blue This indicates the scanner is trying to establish communication with the cradle.

Page Failure Modes Return the unit for repair to an authorized service center. Three Beeps — on power up If the scanner beeps 3 times on power up then the non- volatile memory NovRAM that holds the scanner configuration has failed. If the scanner does not respond after reprogramming, return the scanner for repair to an authorized service center.

Page Upgrading The Flash Rom Firmware The user merely connects the scanner to a communications port of the PC, launches the MetroSet 2 program, and blasts off to new software upgrades. Each MS and its cradle, regardless of the version number or communication protocol, can be upgraded. This label has the model number, date of manufacture, serial number, CE and caution information. Page Connecting To Other Bluetooth Devices A Bluetooth communication between the scanner and the other device must be established before the system works.